 Cleaning
★Satisfied characteristic  of JIS C 5101.
★Aluminum Electrolytic Capacitors may be damaged by corrosion which is caused by any halogenated hydrocarbon solvents (Ex:HCH(Cl)2…). All of our products are non-

solvent-proof,we recommend cleaning method as following:
        Applicable:Any type,any ratings
        Cleaning agents:Pine Alpha ST-100S, Clean Through 750H/750L/710M,Sanelek B-12,Aqua Cleaner 210SEP Techno Care FRW14~17 , Iso- propyl Alcohol
       Cleaning conditions: Total cleaning time shall be within 5 minutes by immersion, ultrasonic or other method.
      (Temperature of the cleaning agent shall be exposure to ozone, ultraviolet rays or radiation.60℃ or lower.) After cleaning, capacitors should be dried using hot

air for minimum of 10 minutes along with the PC board.Hot air temperature should be below the maximum operating temperature of the capacitor. Insufficient dries dry

after water rinse may cause appearance problems, sleeve may shrink, or the bottom-plate may bulge,etc…Please let us know in advance the solvent name and conditions
 for your PWB Cleaning 1-8 Emergency Action

(1)   If you see smoke due to the operation of safety vent, turn off the main switch or pull out the plug from the outlet.

(2)   Do not put your face near the safety vent as gas which in over 100℃ will be emitted when the safety vent operates. If the gas has entered your eyes, please

flush your eyes immediately in pure water If you breathed the gas, immediately wash  out your mouth  and throat with water. Do not ingest electrolyte. If your skin is

exposed to electrolyte, please wash it away using soap and water.
1-9 Storage Condition
(1)Aluminum electrolytic capacitors should not be stored  in high temperatures or where there is a high level of humidity.The suitable storage condition is 5~35℃ and

less than 75% in relative humidity.
(2)Aluminum electrolytic capacitors should not be stored in damp conditions such as water, saltwater spray or oil spray.
(3)Do not store aluminum electrolytic capacitors in an environment full of hazardous gas (hydrogen sulfide , sulfurous  acid gas,nitrous acid, chlorine gas, ammonium,

etc.)
(4)Aluminum electrolytic capacitors should not be stored under exposure to ozone, ultraviolet rays or radiation
(5)If a capacitor has been stored for more than one year under normal temperature (shorter if high temperature ) and it shows increased leakage current, then a

treatment by voltage application is recommended 1-10 Environment-Related Substances All CAPSUN capacitors comply to RoHS (Restricition of Hazardous Substances)

requirements where Chromium VI (Cr+6),Cadmium(Cd),Mercury(Hg),Lead(pb),polybrominated biphenyls (PBBs) and Polybrominated bipheny1/dipheny1 ethers (PBBEs / PBDEs)
have not detected (lower than MDL(Method Detection Limit)) per SGS certification test report 1-11 Disposal
Please dispose capacitors in either of the following ways:
(1)   Incinerate capacitors after crushing parts of making a hole
      on the capacitor body
(2)   Bury capacitors in the ground . Please have a disposal specialist do it.
                                   The Characterisitics of Endurance Tes

TypeInfo: Industry information

Keywords for the information:capacitance  decreasing temperature  the viscosity of the electrolyte  capacitance changes  Temperature(℃)  Capacitance chan